More Power. Built Differently.
The Phoenix DualZone uses two precision-balanced idler motors to provide more combined core steel, copper winding, and usable generating capacity than a same-rated single-idler design. The idlers start sequentially to reduce the peak starting event. Continuous input current is determined by the connected load, so the incoming service, breaker, feeder, and disconnect must be properly sized.
Built for Maximum Output
Connect a properly sized 230V single-phase supply to T1 and T2. Use the model chart below as a starting point, then have a qualified electrician verify the service, breaker, feeder, disconnect, run length, and local code requirements.
Two heavy-duty TEFC cast-iron idler motors work in tandem to generate maximum three-phase output — delivering more combined generating capacity than a same-rated single-idler phase converter.
The DualZone delivers full-rated three-phase power to your equipment. AutoLink auto-starts automatically — giving you maximum phase converter efficiency with zero manual switching.
Installation
Every DualZone ships with a complete installation manual, full wiring diagrams, and a wire and breaker sizing chart. Our Phoenix tech team is available by phone to walk you or your electrician through the install — no charge, no ticket, just pick up and call.
Phase Converter Sizing — Wire & Breaker Chart
Use this chart to size your single-phase input circuit and per-zone output breakers. All final sizing must be verified by a licensed electrician per local NEC requirements.
| Model | HP Zone 1 / Zone 2 | Input Breaker (2-pole) | Wire to Panel | Output Breaker per Zone | Min. Service Required |
|---|---|---|---|---|---|
| GP10/20NL | 10 / 20 HP | 60A | #6 AWG | 30A | 100A |
| GP15/30NL | 15 / 30 HP | 90A | #3 AWG | 40A | 125A |
| GP20/40NL | 20 / 40 HP | 100A | #2 AWG | 60A | 150A |
| GP25/50NL | 25 / 50 HP | 125A | #1 AWG | 70A | 175A |
| GP30/60NL | 30 / 60 HP | 150A | 2/0 AWG | 80A | 200A |
| GP40/80NL | 40 / 80 HP | 200A | 3/0 AWG | 100A | 250A |
| GP50/100NL | 50 / 100 HP | 250A | 350 MCM | 125A | 300A |
| GP60/120NL | 60 / 120 HP | 300A | 400 MCM | 150A | 350A |
| GP75/150NL | 75 / 150 HP | 400A | 500 MCM | 175A | 400A |
| GP100/200NL | 100 / 200 HP | 500A | 600 MCM | 225A | 600A |
* Wire sizes are minimum recommendations at 75°C conductor rating. Actual sizing depends on run length, ambient temperature, and local code. Consult a licensed electrician.
In the Box
Sealed against dust, rain, and washdown. Rated for indoor or outdoor installation.
One per zone. Heavy-duty, totally enclosed fan-cooled. Built to run continuously.
Each zone auto-starts when that load powers on. No manual switching. Standard on every DualZone.
Printed inside the panel and in the manual. Clear connection sequence, no guesswork.
Model-specific breaker and wire recommendations. Inside the panel and in the manual.
Control panel and components covered for the life of the original owner. We stand behind it.
Step-by-step install guide, wiring diagrams, startup checklist, and troubleshooting cards.
Call 800-417-6568 anytime. Real people, free support for the life of your converter.
Common Questions
Call our sizing team — we'll match the right DualZone phase converter to your machines and service, free of charge.
Talk to a Phase Converter Engineer
📞 800-417-6568Free sizing help • Lifetime warranty • Made in USA • Mon–Fri 7AM–5PM MST