Phoenix DualZone™ — Maximum Phase Converter Power

60/120 HP ROTARY PHASE CONVERTER - GP60/120NL Auto-Zoned Power Rotary Phase Converter

★★★★★ 4.9 / 5  ·  250+ reviews
$16,480.00
Free shipping on all orders · Ships from US warehouse
📞 Get a Quote — 800-417-6568
Made in USA NEMA 4 Enclosure Lifetime Warranty TEFC Cast-Iron Idler

More Power. Built Differently.

Twice the Phase Converter Power. Same Single-Phase Service.

The Phoenix DualZone is a rotary phase converter engineered to deliver maximum three-phase power output from your existing single-phase service. Two precision-balanced idler motors work together to generate more capacity, more usable horsepower, and cleaner balanced power than any single-idler phase converter at the same amperage draw.

  • Dual precision-balanced idler motors deliver more total three-phase horsepower from the same single-phase service
  • Cleaner, more balanced three-phase power — ideal for CNC machines, motors, compressors, and sensitive industrial equipment
  • One single-phase input connection powers the entire system — no additional utility service required
  • NEMA 4 sealed control panel — rated for indoor and outdoor installation
  • Lifetime warranty on the control panel — backed by our Phoenix tech team
DualZone dual idler motor setup

Built for Maximum Output

How the DualZone Delivers More Power.

Step 1

Your Existing Single-Phase Service

Connect your existing 230V single-phase service to T1 and T2. The DualZone draws from your current service — no utility upgrade, no new service drop.

⚙️
Step 2

Dual Idler Motors — Double the Power Generation

Two heavy-duty TEFC cast-iron idler motors work in tandem to generate maximum three-phase output — delivering significantly more usable horsepower than a single-idler phase converter on the same service.

🔌
Step 3

Full-Power Three-Phase Output

The DualZone delivers full-rated three-phase power to your equipment. AutoLink auto-starts automatically — giving you maximum phase converter efficiency with zero manual switching.

Installation

Industrial-Grade Phase Converter. Straightforward Installation.

Every DualZone ships with a complete installation manual, full wiring diagrams, and a wire and breaker sizing chart. Our Phoenix tech team is available by phone to walk you or your electrician through the install — no charge, no ticket, just pick up and call.

DualZone wall-mount installation
Wall-Mount Panel Mounts on any solid wall or structure. Idler motors sit on the floor or platform below.
DualZone panel wiring diagram
Clear Wiring Diagram Full wiring diagram included inside the panel and in the manual. T1/T2 input on the right, two 3-phase output blocks on the left.
Single-phase input terminals
Your Existing Single-Phase Service Terminals Bolt-down lug connections on T1/T2. Properly sized wire per the included wire chart.
Second idler motor wiring
Zone 2 Idler Motor The second idler motor connects independently — Zone 2 only runs when that load is active.
Before testing checklist
Before-Testing Checklist A structured checklist walks you through every verification step before you energize — no guesswork.
📄 View the Complete DualZone Installation Manual →

Phase Converter Sizing — Wire & Breaker Chart

DualZone Phase Converter — Wire & Breaker Size Chart

Use this chart to size your single-phase input circuit and per-zone output breakers. All final sizing must be verified by a licensed electrician per local NEC requirements.

Model HP Zone 1 / Zone 2 Input Breaker (2-pole) Wire to Panel Output Breaker per Zone Min. Service Required
GP10/20NL10 / 20 HP60A#6 AWG30A100A
GP15/30NL15 / 30 HP90A#3 AWG40A125A
GP20/40NL20 / 40 HP100A#2 AWG60A150A
GP25/50NL25 / 50 HP125A#1 AWG70A175A
GP30/60NL30 / 60 HP150A2/0 AWG80A200A
GP40/80NL40 / 80 HP200A3/0 AWG100A250A
GP50/100NL50 / 100 HP250A350 MCM125A300A
GP60/120NL60 / 120 HP300A400 MCM150A350A
GP75/150NL75 / 150 HP400A500 MCM175A400A
GP100/200NL100 / 200 HP500A600 MCM225A600A

* Wire sizes are minimum recommendations at 75°C conductor rating. Actual sizing depends on run length, ambient temperature, and local code. Consult a licensed electrician.

In the Box

Every Phoenix Phase Converter ships complete.

🏭

NEMA 4 Control Panel

Sealed against dust, rain, and washdown. Rated for indoor or outdoor installation.

⚙️

Two TEFC Cast-Iron Idler Motors

One per zone. Heavy-duty, totally enclosed fan-cooled. Built to run continuously.

🔗

AutoLink — Both Zones

Each zone auto-starts when that load powers on. No manual switching. Standard on every DualZone.

📋

Full Wiring Diagram

Printed inside the panel and in the manual. Clear connection sequence, no guesswork.

📏

Wire & Breaker Sizing Chart

Model-specific breaker and wire recommendations. Inside the panel and in the manual.

🏆

Lifetime Warranty

Control panel and components covered for the life of the original owner. We stand behind it.

📖

Installation Manual

Step-by-step install guide, wiring diagrams, startup checklist, and troubleshooting cards.

📞

Phoenix Tech Support

Call 800-417-6568 anytime. Real people, free support for the life of your converter.

Common Questions

Phase Converter Questions — Answered.

The DualZone uses two precision-balanced idler motors to generate substantially more three-phase power from the same single-phase service. Where a standard single-idler converter may lose efficiency under heavy loads, the DualZone's dual-motor design maintains cleaner voltage balance and more usable horsepower at the output — especially on demanding loads like CNC spindles, compressors, and multiple simultaneous machines.
Yes. The DualZone is built for exactly that. Multiple three-phase machines can run simultaneously off a single DualZone phase converter — fed through a three-phase sub-panel just like utility three-phase service. Most shops wire the DualZone to a sub-panel and run every machine in the shop from it.
The dual-idler design generates a more stable, better-balanced third phase — particularly under load. Single-idler phase converters can experience voltage imbalance as load increases. The DualZone's second idler motor provides additional generation capacity, improving voltage balance and delivering cleaner power to your equipment across the entire load range.
If you need to run multiple three-phase machines, need more total horsepower than a single-idler converter can deliver cleanly, or simply want the most powerful rotary phase converter available for your single-phase service — the DualZone is the right choice. Call 800-417-6568 and we'll size it for your specific machines and service.
Size the DualZone to your largest single motor, then add 50% for any additional running loads. For example: if your biggest machine is a 20 HP spindle, a GP25/50NL handles that load with headroom for additional equipment. Not sure? Call 800-417-6568 — our sizing team does this every day, free of charge.

More phase converter power starts here.

Call our sizing team — we'll match the right DualZone phase converter to your machines and service, free of charge.

Talk to a Phase Converter Engineer

📞 (800) 417-6568

Free sizing help • Lifetime warranty • Made in USA • Mon–Fri 7AM–5PM MST

Sunday,Monday,Tuesday,Wednesday,Thursday,Friday,Saturday
January,February,March,April,May,June,July,August,September,October,November,December
Not enough items available. Only [max] left.
Add to WishlistBrowse WishlistRemove Wishlist
Shopping cart

Your cart is empty.

Return To Shop

Add Order Note Edit Order Note
Estimate Shipping
Add A Coupon

Estimate Shipping

Add A Coupon

Coupon code will work on checkout page

60/120 HP ROTARY PHASE CONVERTER - GP60/120NL Auto-Zoned Power Rotary Phase Converter

$16,480.00
🔧 Not sure which size? Our engineers will spec it for you — free, no pressure. 🔧 Need sizing help? Free expert advice.
Call Us
Contact Us