Phase Converter Sizing Calculator | Phoenix Phase Converters

Prefer not to use the wizard?

You can size it yourself in three steps, or hand it to us.

  1. Work out the converter size from your motor horsepower and how hard it is to start. The sizing multipliers in the guide below cover this.
  2. Find that size in the table to see the model, breaker range, wire and conduit for a run up to 100 ft.
  3. Buy it online, or call and we will confirm the size and send a written quote with a full bill of materials.
Converter quick reference: model, breaker, wire and conduit by size
Size Model Breaker range Input wire Idler wire Input conduit (EMT) Max output Buy
3 HP GP3NL 10–20 A 10 AWG 12 AWG 1/2" 8 A View & buy
5 HP GP5NL 10–30 A 8 AWG 10 AWG 1/2" 14 A View & buy
7 HP GP7NL 20–50 A 6 AWG 10 AWG 3/4" 20 A View & buy
10 HP GP10NL 30–60 A 6 AWG 8 AWG 3/4" 28 A View & buy
15 HP GP15NL 40–100 A 4 AWG 6 AWG 3/4" 41 A View & buy
20 HP GP20NL 50–125 A 3 AWG 6 AWG 1" 52 A View & buy
25 HP GP25NL 50–150 A 2 AWG 4 AWG 1" 68 A View & buy
30 HP GP30NL 50–150 A 2 AWG 3 AWG 1" 80 A View & buy
40 HP GP40NL 80–200 A 1/0 kcmil 1 AWG 1-1/4" 104 A View & buy
50 HP GP50NL 80–200 A 2/0 kcmil 2/0 kcmil 1-1/4" 130 A View & buy
60 HP GP60NL 100–250 A 3/0 kcmil 2/0 kcmil 1-1/2" 160 A View & buy
75 HP GP75NL 125–300 A 4/0 kcmil 3/0 kcmil 1-1/2" 200 A View & buy
100 HP GP100NL 150–400 A 350 kcmil 4/0 kcmil 2" 260 A View & buy

Planning references for 230 V single-phase supply, copper conductors, runs up to 100 ft. Conduit is EMT sized for the 2 input conductors plus a ground. Compressors, HVAC, other hard-start loads, non-230 V machines and multi-machine shops need a different model or a larger size, so call before you order. Not an installation specification; a licensed electrician sizes and installs to local code.

How to Size a Phase Converter — The Complete Guide

Choosing the right size rotary phase converter is critical to getting full performance from your three-phase equipment. An undersized converter can cause motors to overheat, trip breakers, or fail to start entirely — while an oversized unit wastes money. This guide walks you through the sizing process so you can make the right choice the first time.

Understanding Sizing Multipliers

Not every piece of equipment starts the same way. A table saw spins up easily compared to an air compressor, which must build pressure against a loaded piston. That's why phase converter sizing depends on the starting difficulty of your equipment:

  • Easy-start loads (1.5× motor HP) — Equipment like saws, drill presses, and milling machines that spin up smoothly with minimal starting torque. These are the simplest loads to convert.
  • Medium-start loads (1.75× motor HP) — Mixers and small lathes that need a moderate starting surge. They require a bit more headroom.
  • Hard-start loads (2× motor HP) — Lathes, CNC machines, pumps, press brakes, and wide-belt sanders draw significant inrush current when starting. Sizing at twice the motor HP provides a reliable safety margin.
  • Very hard-start loads (2.5× motor HP) — Air compressors, HVAC units, fans, and hydraulic presses are the most demanding. They start under heavy load and require 2.5 times the motor HP to ensure reliable operation.
  • Resistive loads (1 HP per amp) — Welders, battery chargers, and ovens draw current differently. Size these at 1 HP of converter capacity for each amp of draw.

After applying the multiplier, round up to the next standard converter size. Our GP-NL series comes in 3, 5, 7.5, 10, 15, 20, 25, 30, 40, 50, 60, 75, and 100 HP models — so there's always a size that fits your application perfectly.

Running Multiple Machines Simultaneously

If you're running more than one three-phase machine at the same time, you need a converter sized for the combined total HP of all machines that may operate simultaneously. Add up the horsepower of every machine that could be running at once, apply the highest applicable multiplier, and round up. When in doubt, size up — a slightly larger converter runs cooler and lasts longer.

Checking Your Electrical Service

Your converter needs adequate single-phase power to generate three-phase output. A general rule: your panel should provide at least 2.5× the converter's rated HP in KVA. For a 200-amp, 240V single-phase service, you have roughly 48 KVA available — enough for converters up to about 20 HP, assuming no other major loads. If your calculation suggests a converter that might strain your service, consider upgrading your panel or calling us for a custom assessment.

Why Phoenix Phase Converters?

Every GP-NL phase converter is Built in the USA with industrial-grade components designed for continuous duty. Our proprietary designs deliver balanced voltage across all three phases, which means your motors run cooler, quieter, and last longer. We include a full manufacturer's warranty, and our sizing experts are available at 800-417-6568 to help you get exactly the right unit.

Common Equipment Sizing Reference Table

Equipment Type Start Difficulty 5 HP Motor 10 HP Motor 15 HP Motor 25 HP Motor
Table Saw Easy (1.5×) 7.5 HP 15 HP 25 HP 40 HP
Milling Machine Easy (1.5×) 7.5 HP 15 HP 25 HP 40 HP
Lathe Hard (2×) 10 HP 20 HP 30 HP 50 HP
CNC Machine Hard (2×) 10 HP 20 HP 30 HP 50 HP
Air Compressor Very Hard (2.5×) 15 HP 25 HP 40 HP 75 HP
HVAC Unit Very Hard (2.5×) 15 HP 25 HP 40 HP 75 HP
Hydraulic Press Very Hard (2.5×) 15 HP 25 HP 40 HP 75 HP
Pump Hard (2×) 10 HP 20 HP 30 HP 50 HP

Frequently Asked Questions

What size phase converter do I need for my equipment?▼

Use the sizing wizard above or apply the multiplier for your equipment type: easy-start loads need 1.5× the motor HP, medium-start 1.75×, hard-start 2×, and very hard-start (compressors, HVAC) need 2.5×. Then round up to the next standard converter size. For example, a 10 HP air compressor needs 10 × 2.5 = 25 HP converter.

Can I run multiple machines on one phase converter?▼

Yes! A single rotary phase converter can power multiple three-phase machines simultaneously. Size the converter for the total combined HP of all machines running at the same time, using the highest applicable start-difficulty multiplier. This is actually more cost-effective than buying a separate converter for each machine.

What happens if my phase converter is too small?▼

An undersized converter will produce unbalanced voltage, which causes motors to run hot, draw excess current, and potentially trip breakers or fail to start altogether. Over time, this shortens motor life and can damage sensitive equipment like CNC controls. Always size up if you're between two converter sizes.

Is it better to oversize my phase converter?▼

A slightly oversized converter is always better than an undersized one. It produces better-balanced voltage, runs cooler, handles startup surges more easily, and gives you room to add equipment later. The only downside is a modest increase in upfront cost — but you'll save in the long run with better performance and equipment longevity.

How do I know if my electrical panel can handle a phase converter?▼

Check your main breaker rating — a 200A single-phase, 240V panel provides about 48 KVA. As a rule of thumb, you need about 2.5 KVA per HP of converter capacity. So a 200A panel can comfortably run up to a 15-20 HP converter with headroom for other loads. Our wizard checks this automatically, and our team at 800-417-6568 can help with specific situations.

What is a DualZone phase converter setup?▼

A DualZone setup uses two phase converters working in tandem instead of one large unit. This approach provides redundancy (if one converter needs service, you can still run equipment), better load balancing, and can be more cost-effective for very large installations (25+ HP). It also lets you power equipment in different zones of your shop independently. Call us for a custom DualZone quote.

Phase Converter Applications

We build phase converters for every industry. Explore our application-specific guides for sizing tips, wiring diagrams, and recommendations tailored to your trade:

Still not sure what size you need? Our experts have sized thousands of phase converters for shops, farms, and factories across the country. Call 800-417-6568 for a free consultation — we'll get you the right converter, guaranteed.

Talk to a Phase Converter Engineer

📞 800-417-6568

Free sizing help • Lifetime warranty • Made in USA • Mon–Fri 7AM–5PM MST

Sunday,Monday,Tuesday,Wednesday,Thursday,Friday,Saturday
January,February,March,April,May,June,July,August,September,October,November,December
Not enough items available. Only [max] left.
Add to WishlistBrowse WishlistRemove Wishlist
Shopping cart

Your cart is empty.

Return To Shop

Add Order Note Edit Order Note
Estimate Shipping
Add A Coupon

Estimate Shipping

Add A Coupon

Coupon code will work on checkout page

Call an Expert
Call Us
Contact Us