You can run many three-phase motors from single-phase power using a properly selected phase converter or a compatible variable frequency drive (VFD). The right choice depends on the equipment, motor horsepower, voltage, starting load and whether multiple machines will operate together.
Do not connect a three-phase motor directly to single-phase power. Have a qualified electrician verify the equipment requirements and installation.
A rotary phase converter uses single-phase input power and a rotating generator to supply three-phase equipment.
A correctly selected system can serve applications such as lathes, mills, woodworking machinery, compressors and certain CNC machines. One converter may supply multiple machines, provided its capacity supports their combined running loads and starting requirements.
Equipment compatibility, voltage requirements and manufacturer specifications must be checked. A converter is not automatically suitable for every load.
Browse Phoenix phase converters
A VFD can be a good option when you need variable speed control for an individual compatible motor.
Choose a drive specifically rated for your available single-phase supply and motor. Some drives require derating; others do not accept single-phase input.
A motor-control VFD is generally not a drop-in power supply for an entire machine containing separate controls, transformers or multiple drives. CNC and compressor applications require equipment-specific review—not a blanket yes or no.
A static converter can start certain three-phase motors from single-phase power, but available motor output may be reduced.
Suitability depends on the motor, starting load and converter manufacturer’s instructions. Do not assume a static converter will operate a compressor, CNC machine or multi-motor system correctly.
Start with three details:
Then verify equipment voltage and application-specific starting requirements.
Do not size solely by matching converter HP to motor HP. Compressors, heavily loaded starts and multiple machines can require different selections. Use Phoenix’s sizing guidance rather than a universal multiplier.
Do not assume it will. Phase conversion and voltage transformation are separate requirements. Equipment needing a different voltage may require a properly selected transformer.
Potentially. Selection must account for the machines running together, the largest starting load and equipment compatibility.
Ordinary voltage-reconnection wiring does not convert a three-phase motor into a single-phase motor. Consider a suitable converter, compatible VFD or properly specified replacement motor.
Tell Phoenix what equipment you have, each motor’s horsepower and which machines run together.
Call 800-417-6568 for sizing help.
Talk to a Phase Converter Engineer
📞 800-417-6568Free sizing help • Lifetime warranty • Made in USA • Mon–Fri 7AM–5PM MST