How to Size a Phase Converter for an Air Compressor

Air compressors are one of the most common jobs for a phase converter, and the one people undersize most often. A compressor starts against pressure in the tank, every time it cycles on, all day long. So we size the converter bigger than for a lathe or a saw.

The rule: compressor horsepower × 2.5

Take the horsepower on the compressor motor nameplate and multiply it by 2.5. Round up to the next converter size. That's the size we recommend for both piston and rotary screw compressors.

Example: a 7.5 HP compressor × 2.5 = 18.75, so you need a 20 HP converter (GP20NL).

Sizing chart for air compressors

Compressor motor Math Converter (NL) Upgrade with AutoLink (NLA)
2 HP 2 × 2.5 = 5 GP5NL GP5NLA
3 HP 3 × 2.5 = 7.5 GP7NL GP7NLA
5 HP 5 × 2.5 = 12.5 GP15NL GP15NLA
7.5 HP 7.5 × 2.5 = 18.75 GP20NL GP20NLA
10 HP 10 × 2.5 = 25 GP25NL GP25NLA
15 HP 15 × 2.5 = 37.5 GP40NL GP40NLA
20 HP 20 × 2.5 = 50 GP50NL GP50NLA
25 HP 25 × 2.5 = 62.5 GP75NL GP75NLA
30 HP 30 × 2.5 = 75 GP75NL GP75NLA

Bigger than 30 HP? Call us. At that size we also check your building's service, because the converter has to be smaller than the kVA of your utility transformer. If your service is limited, a DualZone (two smaller idlers that start one after the other) is usually the answer.

NL or NLA?

The NL is our standard converter and runs a compressor fine. The NLA adds AutoLink: after a power outage it starts the converter first, then connects the compressor once the converter is up to speed. Nobody has to be there to restart things in the right order, and the compressor never tries to start on a converter that isn't running yet. If your compressor runs unattended, the NLA is worth it.

Running a compressor with other machines

A compressor cycles on by itself whenever the tank pressure drops, so it can start while your other machines are already running. Size it like this: compressor HP × 2.5, then add the horsepower of every other machine that runs at the same time at 1×.

Example: a 7.5 HP compressor and a 7.5 HP planer: 7.5 × 2.5 + 7.5 = 26.25, so you need a 30 HP converter (GP30NL).

Is your compressor 460 volts?

Many compressors can be rewired from 460 V to 230 V; check the nameplate or the wiring diagram on the motor. If it can't be rewired, we have converters with a built-in transformer (NLT) that take 230 V single-phase in and put 460 V three-phase out.

Not sure of the horsepower? Text a photo of the motor nameplate to 800-417-6568, or call the same number and we'll size it with you.

Want us to check your sizing?

Call 800-417-6568 with your machine list. Every Phoenix converter comes with a lifetime warranty on the control panel; the idler motor carries a 3-year warranty from the motor maker.

Talk to a Phase Converter Engineer

📞 800-417-6568

Free sizing help • Lifetime warranty • Made in USA • Mon–Fri 7AM–5PM MST

domingo,lunes,martes,miércoles,jueves,viernes,sábado
enero,febrero,marzo,abril,mayo,junio,julio,agosto,septiembre,octubre,noviembre,diciembre
No hay suficientes ítems disponibles. Solo quedan [max].
Agregar a favoritosRevisar favoritosRemover favoritos
Bolsa de compras

Tu bolsa de compras está vacía.

Volver a la tienda

Agregar notas a la orden Editar notas de la orden
Estimar envío
Agregar un cupón

Estimar envío

Agregar un cupón

Tu código de cupón se aplicará en el checkout

Call an Expert
Call Us
Contact Us