The Haas VF-4SS (Super Speed) is the high-speed variant of the VF-4 with a 30 HP spindle at 12,000 RPM. Designed for aluminum and high-speed steel finishing.

What Phase Converter Does the Haas VF-4SS Need?

CNC machines are "hard loads" requiring a converter sized at 2× the spindle HP. The Haas VF-4SS has a 30 HP spindle, so:

Undersizing causes voltage sag, spindle faults, and nuisance tripping. The 60 HP gives you the startup torque Haas equipment demands. Questions? Call (800) 417-6568 — free sizing help.

Haas VF-4SS Specifications

Model Haas VF-4SS
Spindle HP 30 HP (max 40 HP)
Spindle Speed 12,000 RPM
Recommended Converter GP60NL — 60 HP

Why GP60NL?

  • Correctly sized for CNC hard-load startup inrush
  • Balanced three-phase output — stable under full spindle load
  • Auto-start NL series — no button, energizes with power
  • Made in Phoenix, Arizona — lifetime warranty included

Ready to power your Haas CNC?

Free sizing help from engineers who know Haas machines. Lifetime warranty. Made in Phoenix, AZ.

Shop Phase Converters →

(800) 417-6568 — Free Sizing Help

Related Resources

Frequently Asked Questions

Can I run my Haas CNC on a rotary phase converter?

Yes — Haas machines run on phase converters every day in shops across the country. The key is correct sizing using the 2x multiplier on spindle HP. Do not undersize.

Will a phase converter damage my Haas control?

No — a properly sized and balanced Phoenix Phase Converter delivers true three-phase power that is functionally identical to utility three-phase. Haas's internal servo drives and spindle VFD operate normally.

What voltage does my Haas need?

Most Haas VMCs are configured for either 230V or 460V three-phase. Check your machine's main disconnect label or electrical panel inside the cabinet. Phoenix NL/PL Series covers 230V output. NH/PH Series covers 460V. Call us if you need help confirming your machine's voltage.

Do I need to do anything special with my Haas when using a phase converter?

No special Haas configuration is needed. Power your converter first, wait 3–5 seconds for the idler to reach speed, then power on your Haas machine normally via the main disconnect. The Haas control will boot and operate as normal.

What size breaker do I need for the phase converter?

Your single-phase input breaker should be sized at approximately 2x your equipment's three-phase full-load amps (FLA). For specific wire and breaker sizing, call (800) 417-6568 with your machine's FLA from the nameplate.

Will the phase converter affect Haas's rigid tapping or high-speed machining?

A correctly sized, balanced phase converter does not affect rigid tapping, high-speed machining, or any other Haas function. Voltage imbalance (from an undersized converter) can cause issues — which is why correct sizing is non-negotiable.

Ready to power your Haas?

Free sizing help from engineers who run Haas machines on converters daily. Made in Phoenix, AZ. Lifetime warranty.

Shop Phase Converters

(800) 417-6568 — Free Sizing Help

Related Resources